Supplementary_Material_Dai (1).docx (552.38 kB)
Download fileA Single-tube multiplex real-time polymerase chain reaction for HLA-B*38:02 genotype by detecting highly specific SNPs - Supplementary_Material
dataset
posted on 2023-01-20, 09:47 authored by Fei Wang, Wenqi Li, Xuan Wang, Xiang Luo, Penggao DaiFigure S1 Fluorescence amplification curves of HLA-B*38:02 sample and negative samples (A)Fluorescence amplification curves of HLA-B*38:02 sample and B*13:01/B*44:02/B*39:01 samples; NTC, non-template control (B) Fluorescence amplification curves of HLA-B*38:02 sample and B*07:02/B*38:01/B*56:07 samples; NTC, non-template control (C) Fluorescence amplification curves of HLA-B*38:02 sample and B*46:01/B*40:01/B*51:01 samples; NTC, non-template control (D) Fluorescence amplification curves of HLA-B*38:02 sample and B*54:01/B*51:02 samples; NTC, non-template control
Table S1 The genotyping results of 100 DNA samples by PCR-SBT and the established Real-time PCR